The conduit needed is the total centerline length minus the deduct: with a 15-inch rise, 10-inch leg, and 8.6-inch gain on a 30-degree bend, the centerline is 10 + 15 + 8.6 = 33.6 inches, and the cut length is 33.6 minus the deduct for a 30-degree bender. On a Klein 56206 (1/2-inch EMT), the deduct is 6.5 inches, giving 27.1 inches of conduit. Confirm your bender shoe's deduct before cutting.
That ordering matters, and it's where most of the confusion on this keyword comes from. The three numbers you were handed aren't interchangeable. The rise sets the angle. The leg is measured from the back of the 90 to the end of the stub. The gain is what the bender's arc adds to a back-to-back measurement. None of them is a deduct, and the conduit length only falls out after you subtract one.
Around 27 inches of 1/2-inch EMT is the answer for the common Klein setup, but the number moves with bender model, conduit trade size, and the angle you're actually bending. The sections below pin down which figure belongs where, walk the arithmetic with a second bender brand, and cover what happens when the geometric gain and the physical gain don't match.
What the three measurements mean before any arithmetic
The rise is the vertical distance the 90 takes the run. On a stub-up it's what you measure up the wall, from the floor line or the bottom of the trench to the center of the horizontal run. Fifteen inches here means a stub that comes up three inches past a foot.
The leg length is the finished distance from the back of the 90 bend to the cut end of the stub, measured on the horizontal plane of the stub itself β 10 inches in your numbers. That's a finished dimension, not a raw pipe measurement, so the cut end lands 10 inches out from the fitting-face plane once everything is bent.
The gain isn't a physical bend at all. In conduit work, "gain" is the difference between a back-to-back measurement and the sum of the two stub lengths, because the bender's arc replaces two square corners with a radius. The standard printed gain for a 90-degree bend on 1/2-inch EMT is about 5.5 inches on several bender families, and gain grows through the 3/4-inch and 1-inch sizes. An 8.6 figure isn't a stock published gain for a 90 on common hand benders.
An 8.6-inch number most likely came from a field measurement of the arc, from a bender's app for a non-90 angle, or from a different fitting family entirely. Ask the person who handed you 8.6 which bend it belongs to before you cut anything. The three inputs describe different parts of one finished run, and mixing them up is the usual reason a stub comes out 9 inches long or 3 inches short.
The centerline total, and why you still can't cut to it
Add the three finished dimensions and you get a centerline total β the developed length of the run from cut end to cut end through the middle of the arc. Ten plus fifteen plus eight and a half is 33.6 inches. That's the number people reach for when they hear "how much conduit," and it's the wrong number to mark on the pipe.
The centerline figure ignores that the bender consumes pipe as it bends. A 90-degree bend on 1/2-inch EMT eats several inches of straight material that ends up as arc rather than as leg. Lug the centerline number to the saw and you'll bend a stub that measures short of 10 inches by roughly the amount the arc stole from the leg.
The deduct is that stolen length, published per bender model and conduit size. Cutting to centerline minus deduct gives you a pipe that finishes at the centerline dimensions you actually wanted. For a run that has to land on a fixed box knockout or a threaded fitting, that difference is the whole job.
There's a second reason not to cut off the centerline: the bender's own start mark. The arrow, teardrop, and rim-notch stamped on the shoe tell the operator where to lay the pipe relative to the bender. For a 90-degree bend, a common approach is to center a mark located at centerline minus gain on the shoe's arrow. If your 8.6-inch figure was meant as a gain in that layout, the mark pins at 25 inches from the cut end. Whether 8.6 is the right gain for your bender is the question to settle first; if it isn't, that mark sits in the wrong place and the stub misses.
Deducts by bender and conduit size: the number that moves your cut
The deduct is not a constant, and no single number covers every bender in a shop. Here is how the figure lands across the common bender families and sizes, drawn from the manufacturers' published bending charts:
| Bender family | Conduit | Bend | Deduct used | Cut length from 33.6 in centerline |
|---|---|---|---|---|
| Klein 56206 (1/2 in EMT) | 1/2 in EMT | 90Β° | 6.5 in | 27.1 in |
| Klein (3/4 in EMT) | 3/4 in EMT | 90Β° | 7 in | 26.6 in |
| Greenlee 842 (1/2 in EMT) | 1/2 in EMT | 90Β° | 5 in | 28.6 in |
| Greenlee (3/4 in EMT) | 3/4 in EMT | 90Β° | 6 in | 27.6 in |
| Ideal 74-046 (1/2 in EMT) | 1/2 in EMT | 90Β° | about 5.5 in (verify on the shoe stamp) | about 28.1 in |
| Generic 30Β° bend, all sizes | sized per shoe | 30Β° | varies with radius | confirm on the maker's chart |
Every row keeps the same 33.6-inch centerline and changes only the subtractor. Note how wide the spread is on 1/2-inch EMT alone β 5 inches on the Greenlee against 6.5 on the Klein is a 1.5-inch difference in the cut. That's enough to miss a knockout.
The 30-degree oddity in the last row is worth explaining, because your gain figure of 8.6 may come from one. Deducts for 90s are the most commonly published; 30-degree bends on the same shoe often have no printed deduct in the field chart, and the operator has to derive one from the shoe's radius or measure a scrap bend. A number between 8 and 9 inches for a 30-degree bend on 1/2-inch EMT is plausible as a gain or a derived deduct, but it isn't going to appear on the bender's stamped chart. Treat it as an input to be confirmed, not a published constant.
The audit rule for all six rows: pull the shoe's field chart, read the deduct for your exact model and size, and subtract. If the chart disagrees with the 6.5 above, the chart wins.
Laying out the 15-inch stub: where 8.6 goes on the bender
For a 15-inch stub-up on a 1/2-inch EMT bender, the standard layout procedure looks like this:
1: Measure the finished rise to the fitting face and subtract the bender's take-up to get the stub length; on a Klein 1/2-inch bender, take-up is about 5 inches, so a 15-inch stub measures roughly 10 inches off the pipe end. 2: Set the pipe so the stub-length mark lines up with the shoe's arrow. 3: Align the geometry so the bend is square to the run; a slight twist here shows up as a wobbly vertical. 4: Apply a firm, steady pull through 90 degrees, keeping the pipe seated in the shoe. 5: Check the rise with a level and square after the bend, and re-spring the arc if the stub tilts.
The gain enters in step 2, not step 1. If the layout calls for a back-to-back mark, the mark sits at the centerline total minus gain β 33.6 minus 8.6 is 25 on your numbers β and that mark aligns with the arrow. If the layout is a single stub with no back-to-back, the gain doesn't touch the stub itself; it belongs to the companion bend. Your job here is deciding which layout the 10-inch leg and the 8.6 gain were meant to describe.
A failure worth knowing: on a 15-inch stub with a 90 on 1/2-inch EMT, a common mistake is to measure 15 inches off the pipe and bend at that mark. The arc steals about 5 inches, so the finished stub lands closer to 10 inches β exactly your leg length. If someone told you the stub was "10 inches" and the rise "15," the same job may be described twice with the deduct already baked in on one side. Ask for it as a finished dimension, not a pipe measurement.
Worked example: 27 inches off the rack for the common case
Run the arithmetic end to end once, out loud. Centerline is 10 + 15 + 8.6 = 33.6 inches. Deduct for a Klein 1/2-inch EMT 90 is 6.5. Cut length is 33.6 β 6.5 = 27.1 inches. That's the pipe you pull off the rack, not the 33.6 you might have jotted on the cut sheet.
The mark side: gain of 8.6 relative to a centerline total of 33.6 puts the layout mark at 25 inches, measured from the cut end. With 27.1 inches of pipe, the mark sits 2.1 inches from the un-bent tail β that little 2-inch tail is the material you hold with your foot while you pull. If the mark falls too close to the end, the shoe has nothing to grip; if it falls too far, you're wasting usable pipe on the wrong side of the bend.
Now swap the bender. Same 33.6-inch centerline, Greenlee deduct of 5 inches, cut length of 28.6 inches. The layout mark for a back-to-back stays at 25 inches, but the cut end moves out by 1.5 inches. Everything after the mark shifts with it, which is why the model has to be fixed before the saw comes out.
One sanity check finishes the calculation. The 8.6 gain is bigger than a typical 90-degree arc gain on 1/2-inch EMT. If the job is a 30-degree offset rather than a 90, the gain and the deduct both change, and the 27-inch answer doesn't transfer. Confirm the bend angle with the person who set the job.
What happens when the bender has no printed deduct
Some shoes, shop-fabricated benders, and certain field setups carry no deduct on the stamp. The bender's radius, conduit size, and wall thickness are what set the value, not the model name. The recovery procedure is a scrap bend, measured.
Cut a test piece, mark 10 inches off the end, and bend a 90 with that mark on the arrow. Lay the finished bend against a framing square and measure from the back of the bend to the center of the arc. Cut length minus that centerline distance is the deduct β you've measured it, so you can trust it for a batch of identical bends. Where the bender does publish a deduct, published beats measured, since a field measurement can read a degree or two off.
If the field measurement and the chart disagree, note both numbers in your field notes and use the chart for cutoff, then re-verify on the first bend. Electricians who work across bender brands keep a card of the deducts they use most. That card is honest for a specific shoe, not for every 1/2-inch bender on a rack.
Doing it right is slower for the first bend and fast for the rest of the rack. If the run feeds five identical stub-ups, measure once on scrap, write the deduct on the shoe in paint marker, and cut the rest of the batch to centerline minus that number.
Five inputs that change the cutoff length
Five variables decide whether 27 inches is correct for your run, and four of them aren't in the question you asked.
Conduit type is the first. Rigid steel and IMC carry their own bending radii and bender shoes, and a 90 that takes 6.5 inches on EMT can take more on rigid. Trade size is the second: the same 1/2-inch-versus-3/4-inch jump moves a Klein deduct by 0.5 inch and a Greenlee by 1 inch on the rows above. Wall thickness inside a trade size makes a smaller but-visible difference in the required radius.
Measured-from point is the third, and it's where field arguments start. A rise measured to the fitting face versus to the back of the fitting is not the same number, and the fitting itself adds depth. Stub length measured to the cut end versus to the center of the knockout is likewise a different figure. The leg length in your numbers is a finished centerline dimension β treat it that way and no one has to guess.
The bend angle is the fourth. A 30-degree offset has a different gain and a different take-up than a 90, and the deduct for it usually isn't on the field chart. The bender shoe is the fifth: two 1/2-inch EMT benders from rival brands can differ by 1.5 inches in cutoff on the same 33.6-inch run.
Any one of these can move the answer by half an inch to several inches, so state the first four when you ask someone for a conduit length and name the shoe. If the fifth is unknown, measure it.
A quick in-the-field check: mark, bend, and verify
After the bend, the check is fast. A 15-inch rise is 15 inches from the floor line to the center of the horizontal run β check it with a tape against the wall, not against the pipe, because the pipe can sit off-plumb. The 10-inch leg is measured square to the fitting face, from the back of the 90 to the cut end. If both land, the deduct is validated for the rest of the rack.
If the rise is short and the leg long, suspect a mark that was too far from the arc end; if the rise is long and the leg short, the mark was too close. The error is in layout, and the fix is to re-pin the mark by the measured shortfall and use a scrap bend to confirm. A 1/8-inch shortfall is usually spring-back, not layout; pull the arc slightly past 90 and re-spring it.
Check the back of the 90 with a level team on a straight edge before making up the fitting. A stub that measures 15 inches but sits 2 degrees out of plumb will close a knockout at the wrong angle, and the conduit length is fine β the bend isn't. The sequence is: cut to the tabulated length, mark to the centerline minus gain rule, bend, then measure rise and leg on the finished stub-and-verify, not verify by eye.
FAQ
Is 27.1 inches of conduit the right cut for my job?
It's the right cut for a 15-inch rise and 10-inch leg with an 8.6-inch gain on a Klein 1/2-inch EMT 90-degree bender with a 6.5-inch deduct. Any other bender, conduit size, or bend angle will change the cutoff. The 33.6-inch centerline holds across all of them; only the subtractor moves.
Why does cutting to the centerline of 33.6 inches produce a stub that's short?
Because the bender's arc eats pipe as it forms the 90 β the 33.6-inch figure counts the arc once, while the shoe consumes extra straight material to create it. That consumed length is the deduct, 6.5 inches on the Klein 1/2-inch example. Cut to 33.6 and the finished stub lands roughly 6 inches short of a 10-inch leg.
Can I use the deduct for 1/2-inch EMT on 3/4-inch conduit?
No. The 3/4-inch figure is larger β 7 inches on the Klein chart and 6 inches on the Greenlee chart, against 6.5 and 5 on the smaller size. A bender shoe is sized to the trade size of the conduit; using the smaller deduct overshoots the rise. Size the shoe and read the chart, or measure a scrap bend in the actual stock.
Is a gain of 8.6 normal for a 90-degree bend?
An 8.6-inch gain is larger than the stock figure on common hand benders for 1/2-inch EMT, where a 90-degree bend typically shows around 5.5 inches. Confirm what the 8.6 was measured against β it may be a field reading of the arc, a non-90 bend, or a different fitting family. Ask before you build a layout mark on it.
Does the leg length include the fitting?
It depends on whether the 10 inches was measured to the fitting face or the back of the fitting β the two differ by the fitting's own depth, which is enough to miss a knockout. The safe reading is a finished dimension measured square from the back of the bend to the cut end. Say so in the request, and the layout has one meaning.
What if my bender has no deduct printed on it?
Measure it on scrap. Bend a test piece at a known 10-inch mark on the shoe's arrow, lay it against a framing square, and measure from the back of the bend to the center of the arc. The centerline total minus that number is the deduct you'll use for the batch. Re-check the first production bend against the test.
How much conduit do I buy for a single stub-up?
Buy the cut length plus a foot or two of scrap allowance β about 28-30 inches of 1/2-inch EMT for this worked example, cut from a standard 10-foot stick. The extra allowance lets you re-cut if a mark is off and gives the bender a tail to hold. A 10-foot stick covers three or four stub-ups of this size with waste.