Advocate Health's suicide risk screening pathway uses the Columbia-Suicide Severity Rating Scale (C-SSRS) — most commonly its six-question Screener version — and, for pediatric and adolescent patients, the three-question Ask Suicide-Screening Questions (ASQ) in many Advocate locations. The tool itself is only half the answer: Advocate pairs the screen with a safety assessment, a level-of-care decision, and documentation in its electronic health record. Which instrument a given patient receives depends on age, setting, and presentation.
The query is narrow but practical. Readers are usually nurses, clinicians, students, or family members trying to pin down the exact instrument used across Advocate Health's Illinois and North Carolina markets so they can align their own workflow, complete a training module, or check a chart. Below is what the evidence base says about both tools and how a large U.S. health system typically operationalizes them, with the caveat that local policy versions and site-level variation always win.
A quick scope note before anything else: this article explains the general screening and assessment pathway. It does not give you a decision rule for a specific patient. Individual risk decisions belong with a qualified clinician who knows that person, and if there is immediate danger, the emergency or crisis line is the first call.
Why Advocate Health Screens With Validated Instruments Rather Than Informal Questions
A validated instrument earns its place because it produces a score (or binary screen result) that stays the same no matter who administers it, whereas "do you feel safe?" varies wildly between nurses. The C-SSRS lists 2011 or later adaptations from the Columbia Lighthouse Project, and its Screener version has been translated into more than 100 languages. A structured tool also creates a defensible record: the scored answer sits in the chart with a timestamp.
The Joint Commission's National Patient Safety Goal 15.01.01 pushes hospitals in this direction. It requires accredited behavioral health organizations to screen for suicidal ideation and risk with a validated tool at intake and to assess anyone who screens positive. Advocate Health's broad medical-surgical footprint isn't automatically bound by NPSG 15.01.01 in every unit, which is precisely why the system's own suicide-prevention policy—not the Joint Commission—sets which tool each unit uses and what "positive" triggers.
That distinction matters for readers verifying the answer. "Advocate uses the C-SSRS" is right in the general case and wrong for any unit whose policy names a different instrument. Start with the local policy document, then the training module, then the chart.
Scoring anatomy separates these instruments. The C-SSRS runs to six questions in Screener form, with the patient asked to choose yes or no and name the nearest time window—lifetime, past month, or past three months depending on the item. The ASQ asks four core questions plus an optional fifth about the past week. That asymmetry shapes what each tool is fast at catching and what it is not built to catch.
Nurses doing this work describe the conversation as clipped and deliberate: straightforward, spoken verbs ("Have you wished you were dead?"), no room to soften the words, and a charting box answered before moving to the next patient. The screen is designed to be short, uniform, and repeatable, and that brevity is why it survives a busy shift.
The C-SSRS: Structure, Versions, and Why Most Advocate Medical Floors See the Six-Question Screener
The C-SSRS screens the range of suicidal thinking and behavior, not just one "suicidal" flag. Its full version spans ideation severity, ideation intensity, behavior, and lethality across roughly two to six pages depending on clinical use, with the Screener and the self-report versions shortened to sprint-length. The Screener's six items ask about wanting to be dead, active ideation, methods, intent, a plan, and suicide behavior—each answered on a time frame.
A handoff detail that rarely makes the policy summary: the C-SSRS records a "no" to a behavior question as a finding, not a clearance. Someone can pass the ideation items and still have a past attempt on the behavior item, and that single positive answer changes the disposition conversation entirely. Repeated screens are often re-administered at discharge or when a ward re-screens, so a quiet floor outcome on admission does not close the file.
A common charting failure: a nurse writes "denies SI" and skips item 6. That erases the behavior question's answer and leaves the record incomplete for anyone auditing the screen later.
Here is how the instruments contrast side by side, so a reader can see what each is actually asking.
| Instrument | Items | Typical age | Time frame | Output | Best suited to |
|---|---|---|---|---|---|
| C-SSRS Screener | 6 | Adults; adolescent versions exist | Lifetime, past 1–3 months | Binary positive/negative plus severity level | Medical floors, emergency departments |
| C-SSRS Full | Full-length | Adults | Lifetime, recent | Severity, intensity, behavior, lethality | Behavioral health, research |
| ASQ | 4 + 1 optional | Ages 10–24 | Recent weeks, past week | Binary positive/negative | Pediatrics, adolescent intake |
| PHQ-9 | 9 | Adults | Past 2 weeks | 0–27 score | Depression severity, not suicide risk |
The PHQ-9 appears here only as a contrast. Item 9 is a single suicide thought question and it is not a risk tool on its own, yet charts sometimes show it treated as one. That is the instrument mix-up readers should watch for.
The ASQ's Three Questions: Where Advocate Pediatric Screening Parts Ways With Adult Screening
For pediatric and adolescent patients, the ASQ's four questions are short enough that a child can answer them at intake without the adult-length framing. The evidence behind it comes from the National Institute of Mental Health and the validated brief screening protocol built into pediatric emergency and inpatient settings. Children answer the first four; a positive on any one triggers a full safety assessment.
The ASQ is deliberately not a risk calculator. It sorts a room full of ten-year-olds into "answer 4 questions and move on" and "a clinician sits down with this patient today." That sorting is the whole function.
Two verbs do most of the ASQ's work: "asked" and "wishing," phrases that include non-suicidal self-injury concerns with the same four-question bluntness as ideation. The clinic flow is ordered, waiting-room quiet, the child answering at a chair while a parent is asked to wait outside, no interpretive hedge, then the answer and an urgent flag if any item is affirmative.
A staff nurse reading an ASQ result should keep a simple number in mind: any positive item on the first four is a positive screen. Cutting an ASQ short, or letting the child drop the fourth question, is exactly the result an evidence-based screen is designed to catch—and it is sometimes what a rushed worker records. That is a failure case the policy exists to prevent.
Which age bracket gets the ASQ, and which goes to the C-SSRS Screener, is decided by local policy, not by this article. Families should ask a clinician which version was completed and what the result triggered.
From Positive Screen to Safety Assessment: The Decision Path Behind the Chart Entry
A positive screen triggers a structured safety assessment, and the C-SSRS Safety Assessment version makes that transition visible in the record. The risk assessment looks at ideation, intent, plan, means access, onset and recency of behavior, and protective factors, then records a plan of action. A positive item alone never ends with "patient is fine"; it therefore always opens a further step.
Three real-world outcomes illustrate the pathway. One patient answers yes to active ideation with a plan and admits having stockpiled a firearm — that lands in prompt same-visit psychiatric evaluation. Another answers yes only to the first item, no to methods and intent, and has a supportive family present — that patient proceeds to a documented safety plan. A third answers yes to a past-attempt item but no to current ideation — that patient still receives the behavior conversation, since past attempts carry the highest single-item signal in most risk models.
Put side by side, the two instruments handle these cases differently. The C-SSRS is more granular because it separates suicide behavior from ideation, while the ASQ is more binary. Neither replaces a full clinical assessment.
Three failure modes recur in safety-assessment errors. Failures happen when the assessment is done by whoever is free instead of a specifically trained staff member on a designated roster, when a positive screen is answered with a warm handoff that has no named receiver, and when the EHR's "current in-patient" filter silently clears an urgent-risk item from the problem list. These summaries describe process failure, not patient diagnosis. None of them are individual patient errors.
For readers checking a specific record, the earliest reliable point is the completed screen, then the assessment note, then the disposition order. If two adjacent notes disagree, the later entry does not override the earlier one by default; the clinician writing it does.
Advocate Health's Illinois and North Carolina Footprints: Why the Answer Can Depend on the Campus
Advocate Health formed in 2022 when Advocate Aurora Health (Wisconsin and Illinois) and Atrium Health (the Carolinas, Georgia, and Alabama) combined and facilities across this network generally retain whichever validated tool their site's policy already named. This means the same network can put the ASQ in front of one clinic's sixteen-year-old and a C-SSRS Screener in front of another's.
A practical consequence: staff crossing campuses for float assignments often need the local version of the tool and the local scoring rules. The common refrain from float nurses is that they learned the tool at one campus and re-learned a different version at another. A quick check of the policy binder before the first shift is the routine that avoids charting in the wrong tool.
For patients and families, the practical question is not "which tool does Advocate use" but "which tool did the unit use for me." That answer lives in the chart and in the discharge paperwork, and asking directly is legitimate.
Case-level application must stay with the treating clinician. If you are trying to verify the tool for a specific patient, request the screening note; if you are trying to verify it for a job or training requirement, request the campus policy and the assigned education module.
Training, Auditing, and Why Documenting the Score Proves the Screen Happened
Advocate publishes suicide-risk screening education through its learning portal, and the assigned module carries a version date. Staff verify they completed the module for the policy year in force, not an older year. The verification path is the course-completion page in the learning portal and the campus policy binder; the title of the course alone does not show which tool version it teaches.
Auditing looks for three artifacts in the record: the completed instrument, the date and time of administration, and the documented response to a positive result. A screen completed but never scored in the chart fails audit. So does a score without the corresponding response. A staff educator's warning is that a completed screen is audited as a completed screen—patients are not told the result in the perimeter of a rushed admission sequence.
The tool-version drift is a real failure case. When a policy is updated from a prior instrument to a newer C-SSRS version, health systems often re-version patient forms but not nursing screens, and staff sees the mismatch; this is a documentation mismatch, not a patient diagnosis.
None of this ensures the patient receives care; documentation quality only shows that the screen was administered. That distinction separates a chart entry from a clinical interaction.
Statistical Assumptions and Edge Cases That Change the Answer
Readers often want a single "most-common tool" statistic for the whole system; no public source outlines system-wide utilization by campus, so anyone claiming a single percentage is likely inferring rather than citing. The only defensible answer is a checklist: local policy, training module, chart note, and the site's LGBTQ+ and pediatric modules. That is more work, and more honest.
Two edge cases bend the pathway. First, a patient who is imminently intoxicated or delirious may be unable to answer the C-SSRS honestly because the questions require coherent yes/no response. The pathway is supposed to defer, re-screen once the patient is oriented, and start the safety assessment then. Second, patients on the autism spectrum or with cognitive impairment may give responses that the tool's instrument does not score in the standard way, and the clinician must document that support rather than silently interpreted. These are clinical realities, not errors.
A third edge case: language access. A C-SSRS validated translation exists in many languages, but a rushed interpreter-mediated C-SSRS can produce different responses; a translated instrument that has been validated must be used where available, with a trained medical interpreter. Using a family member to interpret a suicide screen is a reliable way to receive a false-negative pattern.
One more reality: screening catches people. If you are reading this for yourself and the questions resonate, that is exactly what a screen is for, and it is never a diagnosis or a verdict. Emerging evidence comes from the C-SSRS developers at Columbia and the NIMH-backed ASQ authors, and those groups are the ones to track; the policy document's version number dates must be checked, not assumed current.
FAQ
What is the difference between the C-SSRS and the ASQ?
The C-SSRS Screener uses six yes/no items and distinguishes suicidal behavior from suicidal ideation, while the ASQ uses four core items and returns a plain positive or negative result. The C-SSRS fits adult medical and behavioral health settings; the ASQ fits pediatric and adolescent intake, where brevity is prioritized. Neither instrument substitutes for a full clinical risk assessment, and both typically feed into the same built-in assessment step with a documented safety plan.
Is the PHQ-9 a suicide risk screening tool?
No. The PHQ-9 measures depression severity over the past two weeks, and its item 9 records a single suicide-thought question that some clinicians treat as a prompt for further screening. The PHQ-9 score is not a validated suicide risk screen, and it cannot replace the C-SSRS or ASQ. An elevated PHQ-9 may trigger a full screen, but it does not function as one by itself.
How does a positive screen change a patient's hospital stay?
A positive screen typically triggers structured safety-assessment conversation with a designated clinical staff member, an assessment of protective factors and means access, and a documented plan. Depending on responses, the plan may include same-visit psychiatric evaluation or a documented safety plan with follow-up. Disposition depends on the clinician's judgment, because a single yes does not diagnose, and the response is never decided by the screening tool alone.
Does Advocate Health use the same tool at every campus?
No single answer applies system-wide. Advocate Health combined legacy systems with their own suicide-prevention policies, so a given campus may use the C-SSRS Screener, the ASQ, or both in different units and age groups. Staff and patients should verify which instrument the specific unit's policy names rather than assuming the network has standardized it.
What happens if a patient refuses to answer or cannot answer the questions?
An unable patient, whether due to intoxication, delirium, or cognitive impairment, should not be considered cleared by a screen they could not complete. The correct pathway is to defer and re-screen when the patient is oriented, and to start the safety conversation as soon as possible. A non-response is documented, not treated as a negative.
Who should a family member call if they are worried?
A family member noticing warning signs should contact the local emergency department, a crisis line, or the treating clinician rather than waiting for the next screening interval. A suicide risk screening is a conversation, not a diagnosis. Asking directly about suicide does not plant the idea, and most evidence-based tools are built to make asking easier.
Can the tool be wrong?
Yes. Because these screens ask the patient to respond to specific items, someone may answer "no" and still be at risk, or "yes" and be safe from immediate harm, which is why clinicians following the pathway never treat a single result as proof. The screen's purpose is to make the next conversation reliable, not to be the final word. A negative screen in an emergency setting warrants reassessment if the patient's behavior changes, and a positive screen always warrants a full assessment.
This article is general educational information about screening instruments and health-system practice, not a diagnosis, treatment plan, or promise of any outcome for a specific person. Screening tools cannot establish whether someone is safe or unsafe, and a completed screen is not a substitute for evaluation by a locally qualified clinician. Follow the policy and training materials of the specific Advocate Health campus where care is being delivered. If you or someone you know is in immediate danger, contact local emergency services or a suicide crisis line right away.