The responder arriving with the AED should place it at the side of the compressor, switch it on immediately, and follow its voice prompts without pausing compressions to do so. Apply the pads while chest compressions continue, clear everyone only when the AED says "analyze," and deliver a shock within seconds if one is advised.

The rest of this article assumes a specific scenario: CPR is already in progress, someone else is compressing, and rescue breaths are being given or a bag-mask is in use. That detail matters, because the AED carrier's job is not to start resuscitation β€” it is to add defibrillation to a cycle that's already running.

Why "This Point" Means Compressions Already Running

In most real cardiac arrests, the first rescuer starts CPR before anyone thinks about a defibrillator. By the time a second person walks in with the AED, the arrest is minutes old, the compressor is tiring, and every second spent fumbling with a case is a second without blood flow. The AED carrier's arrival is a role change, not a restart, and treating it as a restart is the most common way good intentions cost time.

The evidence base here is unusually stable. The American Heart Association's guidelines, updated in 2020 and still the operative framework in the 2025 revision cycle, are blunt: minimize interruptions in chest compressions, and keep the pause for rhythm analysis and shock delivery as short as the device allows. The European Resuscitation Council's 2021 guidelines say the same thing in different words β€” no more than five seconds between the last compression and the shock, and resume compressions immediately afterward.

So the AED responder's entire performance is judged against one metric: how little flow gets lost. Everything below β€” where you kneel, when you open the pads, how you call the clear β€” is in service of that number.

One more framing point. The person with the AED is usually the least experienced person in the room, because carrying equipment looks like a job for whoever isn't doing anything. That's a trap. The AED is the single most consequential tool at the scene, and its operator needs to be deliberate, loud, and fast rather than deferential.

Placing the AED Beside the Compressor, Not Behind the Victim

Position the AED case on the floor on the same side as the compressor, level with the victim's chest. That single placement decision determines how much the compressor has to move, how easily the pads reach the bare chest, and whether the analyzing voice prompt is audible to the person who has to call the clear.

The error is arriving and setting up at the victim's head, which feels natural because that's where the airway rescuer is. From the head, you have to reach across the victim's body to place the right pad, the compressor has to shift to make room, and the cable stretches across the workspace where someone will eventually step on it. Kneeling at chest level, shoulder to shoulder with the compressor, keeps the working field compact.

If the arrest happened somewhere cramped β€” a bathroom, between rows of seating, a stairwell landing β€” the placement rule bends but doesn't break. Get the device on the floor on the same side as the compressor if there's room; if there isn't, put it where the cable reaches without crossing over the chest and where the analyzing voice can be heard over the compressor counting aloud.

Weather and surface matter at the edges. Wet ground around a pool or in rain doesn't stop you using an AED β€” wipe the chest so the pads adhere β€” but don't let the device itself sit in standing water. Move it a hand's width clear if you can do so without delaying pad placement.

Switching On and Following Prompts While Compressions Continue

Power the unit on before you open the pads, and let it talk while the compressor keeps working. Modern public-access AEDs such as the ZOLL AED Plus, the HeartStart FRx from Philips, and the Cardiac Science Powerheart G5 begin prompting the moment the lid opens or the power button is pressed, and their first instruction is to apply the electrode pads β€” not to stop CPR. The correct response to that prompt is to keep compressing and to get the pads on in parallel.

Do not silence the device. Some models have a volume control, and turning it down because it conflicts with the compressor's counting is a real-world mistake with real-world consequences: the shock advisory and the clear instruction are the two things the AED exists to deliver. If the room is loud, prioritize the device's voice over the counting.

Have a third person call "pads on" once both electrodes are adhered, so the compressor knows the device is ready to analyze. That call is a cue, not a command β€” the compressor keeps going until the AED says "analyze" or a trained team leader calls for a rhythm check.

If you are the only trained person present and nobody else can compress, the sequence changes: you compress, and you talk a bystander through pad placement using the pictures printed on the pad packaging. AED pads carry diagrams for exactly this reason, and untrained bystanders place them correctly more often than rescuers expect when they're told to copy the picture.

Applying the Two Pads Correctly in Under 20 Seconds

Open the chest fully and dry it if it's wet, then peel and stick the pads exactly where the diagrams on the packaging show. The standard anterior-lateral arrangement puts one pad below the right collarbone and the other on the lower left side of the rib cage, roughly in the mid-axillary line. Get both pads on within about 20 seconds of opening the package β€” a target that's achievable with one attempt and unreachable if you're trying to smooth wrinkles out of a pad you've already stuck down in the wrong spot.

Shave the chest only if hair is dense enough that the pad won't adhere at all, and shave fast. A 2022 review of AED use in prehospital settings, published in Resuscitation, identified poor pad adhesion as a recurring cause of failed analysis and spurious "check electrodes" prompts β€” the device can't read a rhythm through air gaps, so a pad lifting at one corner produces delays that look like device malfunction.

Skip the traditional advice to dry the skin with alcohol before applying pads. Alcohol cools the skin and increases impedance, and the pads are designed for dry skin. A towel or gauze gets you a better connection than a swab.

Implanted devices change the target, not the plan. Move the pad at least 8 cm (about 3 inches) away from a pacemaker or ICD generator, which you can usually feel as a hard lump under the skin on the upper left chest. The device can survive a shock β€” the goal is preventing damage to the generator and ensuring current passes through the heart rather than being shunted.

Clearing the Victim at "Analyze" and Delivering the Shock

Clear the victim only when the AED says "analyze" or "do not touch the patient," and make the clear loud and specific. Everyone's hands off the chest, off the mask, off the stretcher, and nobody touching the patient's clothing. Then say it out loud β€” "clear" β€” and make eye contact with each person before the device analyzes.

The analyze pause is where rescuers lose the most flow time, and it's the pause you have the least control over because the device sets its own analysis window. Most modern AEDs analyze in 5 to 12 seconds. You can't shorten that, but you can make sure nothing extends it: pads fully adhered, nobody touching, no oxygen blowing across the chest (turn the mask or nasal cannula away), and no vehicle or machinery vibration if you're in an ambulance.

When the device advises a shock, it will charge itself and prompt you to press the shock button, unless it's a fully automatic model that delivers the shock without input. Say "clear" again, check your own hands are off, and press. Then resume compressions instantly β€” not after you've looked at the screen, not after you've answered a question, but on the AED's "start CPR" prompt or the team leader's call, whichever comes first. The ERC's 2021 guidelines put the target gap between shock and resumed compressions at under five seconds, and that's the number to hold in your head.

If the device advises "no shock advised," resume compressions immediately and keep going. A non-shockable rhythm at first analysis is not a reason to stop β€” it's a reason to keep the chest moving while the next cycle runs.

The Two Pauses That Predict a Worse Outcome

Two timing traps account for most of the avoidable harm in AED-assisted resuscitation: the analysis pause that runs long because people are still touching the patient, and the post-shock pause that runs long because the team relaxes after the shock goes in. Both are invisible in the moment and decisive in the outcome.

According to the AHA's 2020 guidelines, survival with good neurological outcome falls with every increase in per-shock pause length, and a per-shock pause of more than 20 seconds is associated with a measurable drop in survival to hospital discharge compared with pauses under 10 seconds. The single biggest contributor to a long per-shock pause is not device processing β€” it's human activity during the pause: checking a pulse, repositioning a pad, answering a question from a bystander.

A failure case makes this concrete. During a shock, an oxygen mask left on the victim's face with flow running can ignite if a spark or heat source is present near the pads β€” a rare but documented hazard, which is why both the AHA and the ERC tell rescuers to position oxygen delivery devices at least 1 meter away from the pads and to remove or redirect them during shock delivery. If you can't move the mask clear, turn the flow off for the few seconds of the shock.

The second trap is quieter. After a shock, teams often pause to check the monitor or feel for a pulse. Don't. Resume compressions for a full two-minute cycle and let the next analysis tell you what happened. A pulse check after a shock costs time and is unreliable even in trained hands, which is why the guidelines removed it from the post-shock sequence.

Handing Off Compression Duty During the AED Cycle

Use the AED's arrival as the moment to rotate the compressor, and do it during the shock pause rather than on a separate beat. The person who has been compressing since before the AED arrived is fatigued β€” quality drops measurably after about two minutes, per the AHA's 2020 guidelines β€” and the analysis pause is dead time you're already paying for. Swap in the fresh rescuer during that pause so the next compression cycle starts strong.

Say the swap out loud, and name the roles as you reset. "You're compressing, I'm on the AED, you're on the airway" takes three seconds and prevents two people from reaching for the same task. Role confusion during an arrest is how pads get knocked loose and how the shock button gets pressed by someone who hasn't cleared the room.

The AED itself stays with the patient. Don't hand it back to the responder who brought it, and don't pack it up when the ambulance crew arrives β€” the transferring team keeps the pads on and the device attached until the receiving clinicians take over, because the receiving monitor needs to know what the device saw and delivered. Most modern AEDs store event data that can be downloaded later, and that data is part of the patient's record.

If a second AED arrives from a different source, don't run two. Use the one that's already attached and analyzing; switching devices mid-cycle costs a full pad replacement and a new analysis window.

What the AED Operator Says, and When

The AED operator owns the verbal running order, and a short, repeated script prevents most coordination failures. Say the same words at the same points in every cycle so the team learns the rhythm without being told.

The script has four beats: "pads on," "clear" before analysis, "clear" again before the shock with a physical check of each person, and "resume compressions" the instant the device permits. Anything else you say is noise layered over the device's own prompts.

Give the compressor a heads-up before the analysis pause: "analyzing in five" is enough for them to finish the current compression and lift their hands cleanly rather than being surprised mid-stroke. That single phrase is the difference between a five-second pause and a twelve-second one.

After the shock, the AED will prompt "start CPR" on most models. Say it as you say it β€” "resuming compressions, go" β€” so the compressor starts on the word rather than a second later. Two minutes later, the device prompts analysis again, and the cycle repeats until advanced help takes over or the patient shows signs of life.

If the patient does show signs of life β€” movement, groaning, purposeful breathing β€” leave the pads on and the device attached, place them in the recovery position if they're breathing normally, and keep monitoring. Don't remove the pads; a rearrest can happen within seconds, and re-padding costs the time you don't have.

What Changes on a Child, in Water, or With a Pacemaker

Paediatric arrests shift the pad placement and sometimes the energy setting, but they don't change the role of the AED responder. Use paediatric pads or the paediatric setting if the device has one and the child is under 8 years old or under about 25 kg; if neither is available, use adult pads in the anterior-lateral position, ensuring they don't touch each other. The AHA's 2020 guidelines are explicit that adult pads are better than no pads in a paediatric arrest.

For an infant under 1 year, the preferred placement is anterior-posterior β€” one pad on the front of the chest and one on the back β€” which keeps the pads from overlapping on a small torso. This is the placement most often skipped in training, and the one that most often matters in a real infant arrest.

Water changes the preparation, not the decision. Pull the victim clear of standing water, dry the chest, and proceed. Don't delay defibrillation to move someone out of a puddle if the chest can be dried where they are; the ERC's 2021 guidelines warn against the delay more than against the moisture.

Implanted devices, as noted, need the pad moved about 8 cm clear of the generator. A transdermal medication patch on the chest β€” a nicotine or pain patch β€” should be removed and the skin wiped, because the patch can block current and, in rare cases, cause a small burn. And a hairy chest that defeats adhesion is a shaving problem, not a reason to skip the shock.

FAQ

How long should the pause for AED analysis last?

Aim for 5 to 12 seconds, which is the analysis window most modern AEDs run, and treat anything over 20 seconds as a quality failure. The device sets the floor; human activity sets the ceiling. Keeping hands off promptly and having pads fully adhered is what keeps you near the floor.

Can I use an AED on someone who is wet or lying in snow?

Yes, after drying the chest so the pads adhere. Move the victim out of standing water if it takes seconds, but don't delay defibrillation for a puddle. Snow is not a barrier β€” brush it off the chest and apply the pads. The device itself should not sit in water.

What if the AED says "no shock advised"?

Resume chest compressions immediately and continue the two-minute cycle. A non-shockable rhythm at first analysis does not mean the resuscitation is over; it means the device has nothing to shock right now. Keep going until advanced help arrives or the patient shows signs of life.

Do I need to stop CPR to attach the pads?

No. Apply the pads while compressions continue and pause only when the device prompts analysis. The only exception is if the compressor physically cannot work around your hands, in which case coordinate a single brief pause rather than a prolonged one.

Should I check for a pulse after the shock?

No. Resume compressions for a full two-minute cycle and let the next analysis guide you. Pulse checks after a shock are unreliable and cost time that the guidelines say is better spent on compressions. The device's next analysis is the check.

What does an AED cost, and does training change the outcome?

Public-access AEDs typically run from roughly $1,200 to $2,500 depending on model and accessories, with replacement pads and batteries adding $100 to $300 every few years; confirm current pricing with the manufacturer or a licensed distributor. Training matters more than price β€” the AHA's 2020 guidelines emphasize that early defibrillation plus high-quality CPR is what drives survival, and a trained bystander is the variable that most often separates the two.

Can two AEDs be used at once?

No. Use the device already attached and analyzing. Switching mid-cycle forces a pad replacement and a fresh analysis window, costing the flow time you're trying to protect. If a second device arrives, keep it as a spare.

This article is general educational information about bystander resuscitation and is not a diagnosis, treatment plan, or substitute for certified training. Cardiac arrest management depends on the victim's condition, the equipment on hand, and local protocols; follow the guidance of a qualified clinician or your regional resuscitation council, and enroll in a hands-on CPR and AED course before you need it. If someone is unresponsive and not breathing normally, call your local emergency number immediately.